5. SILENT (Silence Mode)
INPUT
Control Object
1. CDS SENSOR
1. COMP
2. R-FAN
3. F-FAN
4. CUSTOM-LCD
CONTENTS
REMARKS
1. Purpose of Silence mode
To reduce refrigerator noise at night by decresing fan RPM to a minimum degree
2. Condition to start
The optical or light sensor in top middle of control panel senses surround light
and Silence mode starts if the amount of light sensed is below the standard value
for
more than 1 minute.
(The mode does not start for initial 240 minutes to prevent down of cooling
performance.)
- Standard value to decide "night" : below 5 ~7 Lux (optical sensor surface)
- Standard value to decide "day time" : above 4~16 Lux
(optical sensor surface)
3. Control Method
Control Mode
F-FAN
R-FAN
C-FAN
Normal
Silence
Load
Control
12V
12V
10V
10V
10V
12V
4. Termination Condition
The mode stops if lux value is above the standard for more than 1 minute.
6. Control of Each Mode
INPUT
Control Object
1. CDS SENSOR
2. R SENSOR
3. F SENSOR
1. F-FAN (14V, 12V, 10V)
CONTENTS
REMARKS
Control of Silence mode : operation mode when the optical sensor feels that it is
night
Normal control : daytime operation mode
(Refrigerator noise is relatively low at daytime.)
Load control : operation mode when inside temperature goes up due to an
increase of load (foods) or frequent door openings.
OPERATION AND FUNCTIONS
Summary of Contents for FRS-T20DA Series
Page 3: ...2 1 EXTERNAL SIZE FRS T20DA EXTERNAL VIEWS ...
Page 4: ...3 FRS T20FA EXTERNAL VIEWS ...
Page 6: ...5 3 Cold Air Circulation Freezer Compartment Refrigerator Compartment EXTERNAL VIEWS ...
Page 42: ...41 RSCR TYPE 1 WIRING DIAGRAM DIAGRAM ...
Page 43: ...42 DIAGRAM CSR TYPE ...
Page 44: ...43 DIAGRAM 2 CIRCUIT WIRING DIAGRAM Main PCB ...
Page 45: ...44 FRONT PCB DIAGRRAM DIAGRAM ...
Page 52: ...CABINET 51 EXPLODED VIEW 1 FRS T20DA ...
Page 53: ...EXPLODED VIEW MECH ROOM 52 ...
Page 54: ...EXPLODED VIEW R Room 53 ...
Page 55: ...54 EXPLODED VIEW F ROOM ...
Page 56: ...55 EXPLODED VIEW F Door ...
Page 57: ...56 EXPLODED VIEW R Door ...
Page 64: ...CABINET 63 EXPLODED VIEW 3 FRS T20FA ...
Page 65: ...EXPLODED VIEW MECH ROOM 64 ...
Page 66: ...EXPLODED VIEW R Room 65 ...
Page 67: ...66 EXPLODED VIEW F ROOM ...
Page 68: ...67 EXPLODED VIEW F Door ...
Page 69: ...68 EXPLODED VIEW R Door ...