8-6. Main PCB ( Inverter Compressor Models )
1
2
3
4
5
6
MICOM
7
* Make voltage ( 12V
→
5V ) to MICOM.
Voltage check of IC#6 (Input :12V,Output : 5V)
Regulator IC(5V)
6
•To check input & output voltage of Fan
▷
#2 : Input
▷
#5 : Output
•Make signal to control inverter compressor RPM. Output : DC 5 ~ 15V
( 85 Hz / 2550 rpm or 122 Hz / 3660 rpm )
-Compressor RPM is up to each condition
( Ambient Temperature, FCP Button etc.)
* To shorten time in PCB checkup
( 1 time pushing is 1 minute.)
* To check when each device does not work (250V,3.15A)
• Receive signal ( 5V ) from the MICOM.
Deliver signal (12V) each electric device.
▷
Check input & output voltage of MICOM and IC7
•When consumer claim about the refrigerator’s temperature follow this.
Change the resistance ( cutting jumper )
Time Shortening
Switch
5
CN16
(Inverter Models Only)
7
Electric Current Fuse
4
Fan Power
Controller
3
Relay Power
Controller
2
Make refrigerator
cooler
1
Check Point
Item
No
F
R
C
down by 3
℃
J18 & J19
Cutting of
down by 1.5
℃
J18
Cutting of
Remark
FRS-U20**