1. How to enter this check mode
; Press the SUPER FRZ. button 5 times while pushing the FRZ. SET button.
2. The Front LED displays the current error code ( if happens ).
; Every time you press the FRZ. Set button, the following value display.
1) The appliance running time. ( From the plug in. )
2) Freezer sensor temperature.
3) Defrost sensor temperature.
4) Refrigerator sensor temperature.
5) Room temperature.
3. How to exit this mode
1) Press the REF.SET button
2) After 4 minutes automatically exit.
4. Error Code
No
1
2
3
4
5
6
7
8
9
10
11
; All Error Code reset, when the relative parts turn into normal.
FUNCTIONS ( Error Display_Basic Model )
Display (Error Code)
Remark
F1
Freezer sensor disconnection or short
r1
Refrigerator sensor disconnection or short
rt
Room temperature sensor disconnection or short
d1
Defrost sensor disconnection or short
dr
Refrigerator Door switch is defective.
dF
Freezer Door switch is defective.
dH
Home Bar Door switch is defective.
C1
Abnormal or defective cycle
F3
Return after defrosting : abnormal or defective
Co
Pull-Down mode display (No error)
d2
Forced Defrost mode display (No error)
16
Summary of Contents for FRU-541 Series
Page 1: ...Mar 2010 S M No FRSU20IA05...
Page 4: ...2 External Size SPECIFICATIONS 3...
Page 30: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM Refrigerant R 134a Type 29...
Page 31: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM Refrigerant R 600a Type 30...
Page 32: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM for Inverter Compress 31...
Page 55: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 54...
Page 56: ...Water System for Dispenser Model 55...
Page 57: ...How to install water line Dispenser models only 56...
Page 58: ...How to install water line Dispenser models only 57...