5. Weak Cooling Trouble Shooting
; Adjust refrigerator sensor OFF point
- Normal sensor resistance. (31.4kohm)
- Cut the J18 and increase sensor resistance. (33.4kohm)
- Cut the J18, J19 and increase resistance. (35.4kohm)
FUNCTIONS
Option
J1
J2
1.5C down
3.0C down
Normal
Weak Cooling happens
-
Cut
Cut
-
-
Cut
26
Summary of Contents for FRU-541 Series
Page 1: ...Mar 2010 S M No FRSU20IA05...
Page 4: ...2 External Size SPECIFICATIONS 3...
Page 30: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM Refrigerant R 134a Type 29...
Page 31: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM Refrigerant R 600a Type 30...
Page 32: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM for Inverter Compress 31...
Page 55: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 54...
Page 56: ...Water System for Dispenser Model 55...
Page 57: ...How to install water line Dispenser models only 56...
Page 58: ...How to install water line Dispenser models only 57...