1. Faulty Start ( Lights OFF, Front PCB Power Dead )
TROUBLE SHOOTING
Power plug or fuse is
connected?
Start
Chage the plug or Fuse
1st power of SMPS
is ON?
Main PCB Fuse is
connected?
Voltage value on
Main PCB is OK?
Wire connection of
Front PCB is OK?
Check the plug connection
from compressor room and to
CN1 of Main PCB
Change the fuse
( on the Main PCB )
Change the Main PCB
Chage Front PCB
Checkup and connect
Front PCB wires
Yes
No
Yes
No
Yes
No
No
Yes
No
Yes
39
Summary of Contents for FRU-541 Series
Page 1: ...Mar 2010 S M No FRSU20IA05...
Page 4: ...2 External Size SPECIFICATIONS 3...
Page 30: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM Refrigerant R 134a Type 29...
Page 31: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM Refrigerant R 600a Type 30...
Page 32: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM for Inverter Compress 31...
Page 55: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 54...
Page 56: ...Water System for Dispenser Model 55...
Page 57: ...How to install water line Dispenser models only 56...
Page 58: ...How to install water line Dispenser models only 57...