2. Freezing failure ( Weak cooling )
TROUBLE SHOOTING
Error CODE
happens
on Front PCB?
Start
Refer to Error display
in Funtion page
Does compressor
operate?
Freezer/Compressor
cooling Fan
operate?
Temperature Fuse is
OK?
Defrost Heater is
OK?
Check the Relay wire, OLP
and PTC
Change the relative Motor
Change the Fuse
( Left up side of Evaporator )
Change the Defrost Heater
( 250W )
No
Yes
Yes
No
Yes
No
No
Yes
No
Yes
Fan Motor
operate?
Wire is connected?
Change Main PCB
Check lead wire
No
Yes
Yes
No
Ice formation on
Evaporator?
Check ice formation and if
refrigerant leak is found, repair
No
40
Summary of Contents for FRU-541 Series
Page 1: ...Mar 2010 S M No FRSU20IA05...
Page 4: ...2 External Size SPECIFICATIONS 3...
Page 30: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM Refrigerant R 134a Type 29...
Page 31: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM Refrigerant R 600a Type 30...
Page 32: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM for Inverter Compress 31...
Page 55: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 54...
Page 56: ...Water System for Dispenser Model 55...
Page 57: ...How to install water line Dispenser models only 56...
Page 58: ...How to install water line Dispenser models only 57...