9. Door opening alarm continues after closing
TROUBLE SHOOTING
Door switch pushing well?
Start
Attach a thin pad on the
door liner or change the
door assmbly.
No
Door switch is soaked
with water or there is
water in the switch?
Change the door switch
Yes
Yes
PCB input is OK?
Repair any disconnection of wires
and defective door switch
No
Yes
Connector insertion to
Main PCB is OK?
Repair the defective connection
No
Yes
No
Check if interior light is ON
Door switch itself is ok?
Change the new
Yes
48
Summary of Contents for FRU-541 Series
Page 1: ...Mar 2010 S M No FRSU20IA05...
Page 4: ...2 External Size SPECIFICATIONS 3...
Page 30: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM Refrigerant R 134a Type 29...
Page 31: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM Refrigerant R 600a Type 30...
Page 32: ...1 Inner Basic Model 2 Basic Model 3 Dispenser Model WIRING DIAGRAM for Inverter Compress 31...
Page 55: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 54...
Page 56: ...Water System for Dispenser Model 55...
Page 57: ...How to install water line Dispenser models only 56...
Page 58: ...How to install water line Dispenser models only 57...