13
INPUT
CONTROL OBJECT
CONTENTS
1.FRZ. SET
2. REF. SET
Defrost Mode
1. How to start
1) Push the ‘LOCK’ button.
2) Push ‘REF. SET’ button 5 times while pushing ‘FRZ. SET’ button.
2. How to proceed
1) Same as normal defrosting.
2) Heater is ON regardless of D-sensor temperature for initial 30 seconds.
( For checking defrosting current)
4-5. Forced Defrosting Mode ( For A/S )
INPUT
CONTROL OBJECT
CONTENTS
1. Freezer-Sensor
2. Refrigerator-Sensor
F/R/C-Fan, Inter Cooler Fan, Magic Room Fan
4-7. Fan Control in each mode.
INPUT
CONTROL OBJECT
CONTENTS
1.Defrost Sensor
2. Initial Power Input
Defrost Mode
1. How to start
1) When initial power input.
2) Defrost sensor is below 3.5 degree.
2. Compressor doesn’t work for 6 Min.
4-6. Initial Defrosting Mode
10V
12V
12V
Load Response
10V
14V
14V
Quick Mode
10V
12V
12V
Normal Mode
Comp. Cooling Fan
Refrigerator Fan
Freezer Fan
Division
1. Fan Voltage in each mode
1) Fan Motor Voltage