INPUT
CONTROL OBJECT
CONTENTS
1. Freezer Door
2. Refrigerator Door
3. Home Bar Door
Freezer Room Lamp
Refrigerator Room Lamp
4-12. Cooling Fan Delay
1. Refrigerator Room Lamp Control
1) Refrigerator Lamp is ON / OFF if refrigerator door switch open / close.
2) Refrigerator lamp is off automatically when refrigerator door switch senses open for 10 min.
3) When refrigerator door switch senses ‘Door Open’ for 1 hour, “dR” Error display on the Front Control Panel.
2. Freezer Room Lamp Control
1) Freezer Lamp is ON / OFF if refrigerator door switch open / close.
2) Freezer lamp is off automatically when refrigerator door switch senses open for 10 min.
3) When freezer door switch senses ‘Door Open’ for 1 hour, “dF” Error display on the Front Control Panel.
3. Refrigerator lamp control by Home Bar switch ( * Home Bar Models Only)
1) Refrigerator Lamp is ON / OFF if Home Bar door switch open / close.
2) Refrigerator lamp is off automatically when Home Bar door switch senses open for 10 min.
3) When Home Bar door door switch senses ‘Door Open’ for 1 hour, “dH” Error display on the Front Control Panel.
INPUT
CONTROL OBJECT
CONTENTS
Front Control Panel
4-13. Pull Down Function
; This function is to verify freezing performance by running all cooling fan and compressor continuously.
1) How to start
- Press the ‘LOCK’ button.
- Push ‘LOCK’ button 10 times while pressing ‘REF.SET’ button.
2) ‘Co’ display in Error Mode.
3) How to end
- After 30 hours.
- Or plug out.
Electrical Devices