Document: After-sales Maintenance Service Manual No.: L32R63*VKE/L40R63*VKE/L43R63*VKE/L49R63*VKE Version: 1.0 Effective from: APRIL 4th, 2016
Page 15 of 49
VII. Power Module Fault Analysis
While checking Standby 5V, 3.3V, and Normal 1,5V, 3.3V, 5V, 12V, Main board must be exchanged if
voltage output is not correct at the power check point on board.
Model
:
L32R63*VKE,
L40R63*VKE
(3in1 board (Power + LED Main))
PQ112 : #2, 5V StandBy
#3, 5V Normal
U8 : #1, 5V Normal
#2, 1.5V DDR
U114 : #3, 5V StandBy
#2, 3.3V StandBy
#4, 3.3V Normal
L204 : 12V Normal, AMP 12V
L32R63_VKE,L40R63_VKE,L43R63_VKE,L49R63_VKE_CIS_Russia.indd 15
2016-04-05 오전 11:00:49