4-30 Inspection, Maintenance and Adjustment
K1000896E Operation and Maintenance Manual
1.
Locate the air filter assembly (Figure 52
and Figure 53). Remove access cover and
remove outer filter of air filter assembly.
NOTE:
If indicator light on instrument
panel comes "ON," this
indicates that air cleaner needs
to be serviced.
NOTE:
Replace outer filter every 1,000
hours of service.
2.
Clean outer filter by blowing compressed
air from inside of filter towards the outside.
Do not use more than 205 kPa (30 psi) air
pressure.
3.
Clean the inside of air filter housing and
inside of air filter housing cover.
4.
Properly reinstall air filter and cover.
Tighten cover wing nut by hand. Do not
use any tools to tighten wing nut.
CAUTION!
Never clean the inside of air filter
housing while the inner element is
not installed.
Figure 52
(S/N 3001 thru 4000)
Figure 53
(S/N 4001 and Up)
HAOC570L
Figure 54