K1000896E Operation and Maintenance Manual
Inspection, Maintenance and Adjustment 4-63
1.
Remove strainer cap (4, Figure 100) from inlet hose.
NOTE:
Keep strainer cap in a safe location to reseal strainer after refueling is complete.
2.
Insert inlet hose (5, Figure 100) into refueling tank.
3.
Turn fuel pump switch to "ON" position.
NOTE:
The transfer pump rate of flow
is approximately 20 liters /
minute (5 gpm). Use extra care
not to overfill fuel tank so that
fuel does not over flow.
4.
Once fuel transfer is completed,
immediately turn switch to "OFF" position
to stop pump.
5.
Lift inlet hose from fueling source and turn
switch to "ON" position for 2~3 seconds to
drain remaining fuel from hose to fuel tank.
6.
Replace strainer cap (4) to inlet strainer
and return hose to storage position.
4
2
1
3
I N
O U T
AHO0790L
5
Figure 100
Figure 101