Track Excavator Safety
Never attempt to alter or modify any type of
protective structure reinforcement system, by
drilling holes, welding, remounting or relocating
fasteners. Any serious impact or damage to the
system requires a complete integrity
reevaluation. Reinstallation, recertification, and/
or replacement of the system may be
necessary.
Contact your Daewoo distributor for available
safety guards and/or recommendations if there
is any danger of getting hit by objects that could
strike the operator's cab. Make sure that all
other work site crew members are kept well
away from the excavator and safe from possible
hazards.
For breaker operation, install a front guard and apply a laminated coating sheet to the front glass. Contact
your DAEWOO distributor for recommendations.
When carrying out demolition or cutting operation, install a front guard and top guard, and apply a
laminated coating sheet to the front glass.
When working in mines or quarries where there is danger of falling rock, install FOPS (Falling Objects
Protective Structure) and apply a laminated coating sheet to the front glass.
If any glass on the machine is broken, replace it with new glass immediately.
ATTACHMENT PRECAUTIONS
Option kits are available through your dealer. Contact Daewoo for information on available one-way
(single-acting) and two-way (double-acting) piping / valving / auxiliary control kits. Because Daewoo cannot
anticipate, identify or test all of the attachments that owners may wish to install on their machines, please
contact Daewoo for authorization and approval of attachments, and their compatibility with options kits.
ACCUMULATOR
The pilot control system is equipped with an accumulator. For a brief period of time after the engine has
been shut down, the accumulator will store a pressure charge that may enable hydraulic controls to be
activated. Activation of any controls may enable the selected function to operate under force of gravity.
When performing maintenance on the pilot control system, the hydraulic pressure in the system must be
released as describe in “Handling of Accumulator” in the Operation and Maintenance Manual.
The accumulator is charged with high-pressure nitrogen gas, so it is extremely dangerous if it is handled in
the wrong way. Always observe the following precautions;
•
Do not drill or make any holes in the accumulator or expose it any flame, fire or heat source.
•
Do not weld on the accumulator, or try attaching anything to it.
•
When carrying out disassembly or maintenance of the accumulator, or when disposing of the
accumulator, the charged gas must be properly released. Contact your Daewoo distributor.
•
Wear safety goggles and protective gloves when working on an accumulator. Hydraulic oil under
pressure can penetrate the skin and cause serious injuries.
HAOA100L
Figure 10
Summary of Contents for Solar 225LC-V
Page 2: ......
Page 4: ......
Page 7: ...1SAFETY ...
Page 8: ......
Page 46: ...S0102000 Page 38 Track Excavator Safety ...
Page 47: ...1SPECIFICATIONS ...
Page 48: ......
Page 54: ...S0205015K Page 6 Specifications for Solar 225LC V Return to Master Table of Contents ...
Page 70: ...S0205015K Page 22 Specifications for Solar 225LC V Return to Master Table of Contents ...
Page 71: ...1GENERAL MAINTENANCE ...
Page 72: ......
Page 86: ...S0302000 Page 14 General Maintenance Procedures ...
Page 99: ...1UPPER STRUCTURE ...
Page 100: ......
Page 102: ...S0402040K Page 2 Cab TABLE OF CONTENTS Removal 3 Installation 6 ...
Page 116: ...S0403050K Page 8 Counterweight Return to Master Table of Contents ...
Page 140: ...S0407000 Page 6 Swing Bearing ...
Page 165: ...1LOWER STRUCTURE AND CHASSIS ...
Page 166: ......
Page 192: ...S0505030 Page 26 Track Assembly Return to Master Table of Contents ...
Page 193: ...1ENGINE AND DRIVE TRAIN ...
Page 194: ......
Page 205: ...S0605060K Page 11 Air Conditioner Face and Defroster ARS1300L Figure 12 ...
Page 229: ...S0609000 Page 9 Drive Coupling Main Pump Figure 10 DRIVE COUPLING INSTALLATION UCHIDA PUMP ...
Page 234: ...S0609000 Page 14 Drive Coupling Main Pump ...
Page 235: ...1HYDRAULICS ...
Page 236: ......
Page 249: ...S0702170K Page 13 Hydraulic System Troubleshooting Testing and Adjustment ...
Page 272: ...S0702170K Page 36 Hydraulic System Troubleshooting Testing and Adjustment ...
Page 274: ...S0703010K Page 2 Accumulator TABLE OF CONTENTS General Description 3 Specifications 4 ...
Page 297: ...S0705000 Page 9 Cylinders ...
Page 301: ...S0705000 Page 13 Cylinders ...
Page 311: ...S0705000 Page 23 Cylinders ...
Page 315: ...S0705000 Page 27 Cylinders ...
Page 324: ...S0705000 Page 36 Cylinders 17 Force out pin bushing 1 from body of cylinder Figure 28 ...
Page 328: ...S0705000 Page 40 Cylinders ...
Page 335: ...S0707200 Page 7 Swing Motor Return to Master Table of Contents ...
Page 341: ...S0707200 Page 13 Swing Motor Return to Master Table of Contents SPECIAL TOOLS Figure 6 ...
Page 358: ...S0707200 Page 30 Swing Motor Return to Master Table of Contents ...
Page 452: ...S0708320 Page 40 Main Pump With Regulator Return to Master Table of Contents ...
Page 458: ...S0709401K Page 6 Main Control Valve Kayaba Figure 1 ...
Page 459: ...S0709401K Page 7 Main Control Valve Kayaba Figure 2 ...
Page 461: ...S0709401K Page 9 Main Control Valve Kayaba ...
Page 463: ...S0709401K Page 11 Main Control Valve Kayaba Figure 4 ...
Page 475: ...S0709401K Page 23 Main Control Valve Kayaba Figure 16 ...
Page 508: ...S0709401K Page 56 Main Control Valve Kayaba Figure 54 ...
Page 563: ...1ELECTRICAL SYSTEM ...
Page 564: ......
Page 618: ...S0802220K Page 54 Electrical System ...
Page 637: ...S0802220K Page 73 Electrical System ...
Page 649: ...1ATTACHMENTS ...
Page 650: ......
Page 670: ......