TOOL OPERATION FOR SETTING BLIND RIVETS 

 

1)  After completing the start-up preparations, place the rivet mandrel into the nosepiece, and 

holding the tool securely, insert the rivet into the pre-drilled hole of the work piece that needs 
to be fastened.  

 

2)  Pull the tool 

trigger (#48)

 to set the blind rivet in its position in the work piece. 

 

3)  After setting the rivet, the used mandrel will be sucked into the 

mandrel collector

 

(#24)

 at the 

back of the tool automatically. Always have the 

mandrel collector

 on the tool when in use, in 

case  a rivet  mandrel  comes  shooting out from the back and causes injuries.  Be sure to 
empty the 

mandrel collector (#24)

 when half full otherwise the tool will not be able to release 

used mandrels properly which can cause serious damage to the tool. 

 

4)  The power of the vacuum can be adjusted to stronger or weaker by turning the knob on back 

of the tool which is visible when the 

mandrel collector (#24)

 is removed. 

 

 
 
 
 

 
 

5)  On the 

air adaptor hose (#53)

 equipped for this tool, there is a sliding switch to pause/switch 

off the air supply to the tool when not in use. 
 
 
 

TOOL MAINTAINANCE 

 

In order to maintain optimum performance after several weeks of regular use, add a few drops 
of hydraulic oil on the inlet of the 

air adaptor (#52)

 of the tool in order to reduce the friction of 

the tool parts, as the oil will be blown inside the tool when it is in operation. 
 

 

 
 
 
 
The tool stroke may be reduced after a period of use, which indicates that the hydraulic oil in 
the pneumatic tool needs to be refilled or changed; 

 

1)  Remove the 

screw (#11)

 with a hexagon wrench: 

 
 