DRPB64V Operation Manual
2) Connect the air supply and to place a cloth over the hole where the
screw (#11)
was
removed, then to pull the
trigger (#48)
and the oil will be forced out from the tool;
3) Screw the
oil inject adaptor (in the oil injector set in the accessories pack)
into the hole where
screw (#11)
was removed;
4) Use the
oil injector (in the accessories pack)
to slowly inject the oil until full (approx. 15ml).
Remove the injector and its adaptor, then clean any excess oil off the tool and tightly screw
the
screw (#11)
back into the tool;
5) Test the tool stroke. If the stroke is still not what it should be, some air could have entered
the
oil cylinder (#13)
while refilling the oil in the tool. To release any extra air from the tool,
connect the tool to the air supply, pull the tool
trigger (#48)
6 or 7 times, then loosen the
screw (#11)
, to let the extra air leak out and then tighten the
screw (#11)
again.