background image

2. Installation  /  

2.1 Installation Safety 

k) Don’t dismantle any components of DAH Solar PV module personally.
l) Please read and well understand all the installation instructions before Installation, connection and maintenance.
m) Don’t lift modules by junction box or connecting cables.
n) All the modules system should be connected to ground, if without special stipulations, please refer to International 
Electrical Standard or other International Standards.
o) After modules delivered to installing site, all the components should be unpacked carefully.
p) Please do not stand, sit, lying on modules, it may damage modules and also have injured risks. 

 
q) Same size and specification models modules can only be connected together.
r) During delivery please make sure transport tools or modules are not subjected to large vibrations,vibrations may 
cause modules damage or cells microcrack inside of modules.
s) During all the delivery, don not allow modules to fall onto ground from transport tools, house or hand, this will 
damage modules or cells inside.
t) Do not wipe the module with corrosive chemicals.
u) When loads are working,please do not disconnect the modules.

◆ Please wear protective headcoats, insulated gloves, and rubber insulated shoes during installation job.
◆ Keep the PV module packed until installation.
◆ To avoid unnecessary touching of the PV module during installation. The surface of modules may over heated, it has risk 
of burnt and electric shock.
◆ Do not install in raining, snowing or windy weather conditions.
◆ Due to the risk of electric shock, please do not proceed the installation work if junction box was wet.
◆ Use insulated and dry tools, do not use wet tools.
◆ Do not throw any objects during installation (such as PV module or tools).
◆ Make sure that combustible gasses are not generated or present near the installation site.
◆ Correctly connect the male and female connectors , inspect the wiring status, all the cables must not be separated from 
the PV module.
◆ Do not touch junction box and the end of the connectors(male and female) with bare hands during installation or under 
sunlight, regardless of whether the PV module is connected to or disconnect from the system.
◆ Do not expose the PV module to excessive loads on the surface of the PV module.
◆ Do not strike or put excessive loads on the glass or back sheet, this may break the cells or cause micro crack.
◆ Do not use sharp tools to wipe the glass of PV module. It would leave scratches on the module.
◆ Do not drill holes on the frame of PV module. 
◆ For BIPV (building integrated photovoltaics) or rooftop mounting structure installation, please try to follow the“from top 
to bottom” and/or “from left to right” principle, and do not step on the module, that will damage the module and would be 
dangerous for personal safety.

05

/

06

P V   M O D U L E   I N S T A L L A T I O N   M A N U A L

Summary of Contents for DHM50 5BB Series

Page 1: ...on Manual Factory No 358 Tianhe Road Luyang Industrial Park Hefei City Anhui China Office Floor 1 3 6 A Gongtou Xinglu Industrial Park Hefei City Anhui China Email sales dh solar cn Tel 86 551 6565584...

Page 2: ...Installation 2 1 Installation Safety 2 2 Installation Condition 2 3 Instruction of Installation Methods 3 Wiring and connection 4 Maintenance 4 1 Appearance Inspection 4 2 Cleaning 4 3 Connector Wires...

Page 3: ...of the other devices connected to the PV array The maximum permitted system voltage DC of the modules is 1500V DC If installed on the rooftop modules must be installed on fireproofing material please...

Page 4: ...to the short circuit current and open circuit voltage of the PV module and design and install the system in 125 of the value as well e In case to lower electric shock or burnt risk it s better to cove...

Page 5: ...ecessary touching of the PV module during installation The surface of modules may over heated it has risk of burnt and electric shock Do not install in raining snowing or windy weather conditions Due...

Page 6: ...sing Please follow the recommendations of the battery manufacturer regarding installation instructions operation and maintenance To ensure that the battery is working properly which should avoid direc...

Page 7: ...g please check the safety performance of the junction box Any body like insects or other things on the surface of solar panels please remove it b Please check and ensure the PV modules serial number a...

Page 8: ...ectors is more than 10A otherwise the connecting cables and connectors will be over heating Please pay attention that the temperature limit of the cables is 85 C e The electrical connections must be p...

Page 9: ...s Connection Parallel Connection Electrical performance parameter of module such as nominal value of Isc Voc and Pmas has 3 random error compared with value of STC The standard Testing Environment of...

Page 10: ...relevant use authorization for use of the products whether express or implied DAH Solar reserves the right to modify the manual PV products specifications or product information the modifica tion of...

Reviews: