2.2 Installation Condition

2.2.1 Climatic Condition

1) Recommended installation ambient temperature is between -40°C to 85°C (-4°F to 185°F).
2) Do not install PV modules in a flooded risk area.

Note: The PV module mechanical load (including the wind and snow pressure) is based on the installation method and installation 
site. During the collection of mechanical load, it must be calculated by a professional installer according to the requirements of 
system design.

2.2.2 Installation Site Selection

In general, the PV modules should be installed in the place with the maximum sunlight thoughout the year.In the northern 
hemisphere, modules should be placed toward south as the first choice, while in the southern hemisphere, it should be 
placed toward north. If the angle of the modules deviate 30 angle away from the South (or North) direction, the power 
output will lose about 10% to 15%, if modules angle deviate is 60 degrees, lose rate is about 20% to 30% of power output. 
The installation site should avoid shadows of tree, building and other obstacles. Module manufacturer have already 
installed the bypass diode to minimize the loss, but the shadow will still reduced output power. 

When the PV system equipped with batteries bank, it must be installed correctly, which can protect the system operation 
and ensure the safety of user during their using. Please follow the recommendations of the battery manufacturer 
regarding installation instructions, operation and maintenance. To ensure that the battery is working properly, which 
should avoid direct sunlight, rain and snow erosion, meanwhile maintaining good ventilation. Most kinds of battery 
charging could release hydrogen which explosion easily happen. It must avoid a fire or make a spark around the batteries 
bank. If the battery installed outdoors, which must the placed in a specially designed area with insulation and ventilation. 
Do not install the PV modules close the naked light or flammable materials. 
Do not install the PV modules in places where it would be immersed in water or continually exposed to water from a 
sprinkler or fountain etc.

If connect to the independent PV system, modules angle should be based on season and sunshine condition to obtain 
the maximum power output. Normally, if module’s power output could be satisfied during the lowest sunshine intensity 
of a year, then this installation angle can meet the demands of the whole year. For grid tie PV system, the installation 
angle selection of the modules should be based on annual power output maximization.

07

/

08

2.2.3 Angle Selection

The angle of the PV modules refers to the angle between module surface and the ground (Figure 1), the output power 
will be maximum when modules are facing the sun in vertical.

Tilt angle

Module PV

Sunlight

Horizontal line

Figure 1 : The installation angle of PV Module

P V   M O D U L E   I N S T A L L A T I O N   M A N U A L

Summary of Contents for DHP60 5BB Series

Page 1: ...on Manual Factory No 358 Tianhe Road Luyang Industrial Park Hefei City Anhui China Office Floor 1 3 6 A Gongtou Xinglu Industrial Park Hefei City Anhui China Email sales dh solar cn Tel 86 551 6565584...

Page 2: ...Installation 2 1 Installation Safety 2 2 Installation Condition 2 3 Instruction of Installation Methods 3 Wiring and connection 4 Maintenance 4 1 Appearance Inspection 4 2 Cleaning 4 3 Connector Wires...

Page 3: ...of the other devices connected to the PV array The maximum permitted system voltage DC of the modules is 1500V DC If installed on the rooftop modules must be installed on fireproofing material please...

Page 4: ...to the short circuit current and open circuit voltage of the PV module and design and install the system in 125 of the value as well e In case to lower electric shock or burnt risk it s better to cove...

Page 5: ...ecessary touching of the PV module during installation The surface of modules may over heated it has risk of burnt and electric shock Do not install in raining snowing or windy weather conditions Due...

Page 6: ...sing Please follow the recommendations of the battery manufacturer regarding installation instructions operation and maintenance To ensure that the battery is working properly which should avoid direc...

Page 7: ...g please check the safety performance of the junction box Any body like insects or other things on the surface of solar panels please remove it b Please check and ensure the PV modules serial number a...

Page 8: ...ectors is more than 10A otherwise the connecting cables and connectors will be over heating Please pay attention that the temperature limit of the cables is 85 C e The electrical connections must be p...

Page 9: ...s Connection Parallel Connection Electrical performance parameter of module such as nominal value of Isc Voc and Pmas has 3 random error compared with value of STC The standard Testing Environment of...

Page 10: ...relevant use authorization for use of the products whether express or implied DAH Solar reserves the right to modify the manual PV products specifications or product information the modifica tion of...

Reviews: