◆ Clamps mounting methods - 

Using special clamps to install the modules

2.3 Instruction of Installation Methods

The Installation methods of DAH Solar 
PV module are screw mounting and 
clamp mounting.

◆ Screws installing method

  Notes:

1. All mentioned clamp mounting methods here are only for reference, DAH Solar will not be responsible for the system design 
and installation. The mechanical loads and its safety must be operated and completed by the professional solar system installer 
and experienced installation team.
2. Please ensure the following points before the clamps mounting:
a) Before the mounting, please check the safety performance of the junction box. Any body like insects or other things on the 
surface of solar panels, please remove it.
b) Please check and ensure the PV modules serial number are correct.
3. DAH Solar PV module (only for the component model involved in this specification) (snow / wind load) product specification 
load 3600 PPA load, back design load of 1600 PPA, safety factor 1.5 times. If modules installed in the snowy and strong windy 
environment, the special protection actions should be taken to meet the installation requirements.

09

/

10

Bolt

Gaskets
Spring gaskets
Nut

PV Module

1

2

3

PV Module

PV Module

PV Module

DHP60-(260-280)-5BB

Rated Power

W

260-280

Dimension(mm)

1650*991*35*35

Installation hole pitch

860; 1360; 941

B

A

P V   M O D U L E   I N S T A L L A T I O N   M A N U A L

Summary of Contents for DHP60 5BB Series

Page 1: ...on Manual Factory No 358 Tianhe Road Luyang Industrial Park Hefei City Anhui China Office Floor 1 3 6 A Gongtou Xinglu Industrial Park Hefei City Anhui China Email sales dh solar cn Tel 86 551 6565584...

Page 2: ...Installation 2 1 Installation Safety 2 2 Installation Condition 2 3 Instruction of Installation Methods 3 Wiring and connection 4 Maintenance 4 1 Appearance Inspection 4 2 Cleaning 4 3 Connector Wires...

Page 3: ...of the other devices connected to the PV array The maximum permitted system voltage DC of the modules is 1500V DC If installed on the rooftop modules must be installed on fireproofing material please...

Page 4: ...to the short circuit current and open circuit voltage of the PV module and design and install the system in 125 of the value as well e In case to lower electric shock or burnt risk it s better to cove...

Page 5: ...ecessary touching of the PV module during installation The surface of modules may over heated it has risk of burnt and electric shock Do not install in raining snowing or windy weather conditions Due...

Page 6: ...sing Please follow the recommendations of the battery manufacturer regarding installation instructions operation and maintenance To ensure that the battery is working properly which should avoid direc...

Page 7: ...g please check the safety performance of the junction box Any body like insects or other things on the surface of solar panels please remove it b Please check and ensure the PV modules serial number a...

Page 8: ...ectors is more than 10A otherwise the connecting cables and connectors will be over heating Please pay attention that the temperature limit of the cables is 85 C e The electrical connections must be p...

Page 9: ...s Connection Parallel Connection Electrical performance parameter of module such as nominal value of Isc Voc and Pmas has 3 random error compared with value of STC The standard Testing Environment of...

Page 10: ...relevant use authorization for use of the products whether express or implied DAH Solar reserves the right to modify the manual PV products specifications or product information the modifica tion of...

Reviews: