Automatic Position Limitation Function Instructions for Apparel
Embroidery
A.
Working Principle
The automatic position limitation function of single-head embroidery machine controller
is to determine the embroidery range of the frame by setting the distance from the center of the
frame to the origin (that is X-/Y position limitation optical coupler) and the actual frame size
(unit: mm). If embroidery is to be done beyond such range, the controller will activate
automatic protection to prevent damage to the mechanical parts of the embroidery machine.
B.
Setting Method
1.
Set Frame Origin
Press
key, then press
key, to enter the following interface.
Select "
⑨
Automatic Origin Search", to enter the interface to search origin automatically;
the frame will search and determine the origin automatically; press "
" key to quit.
A15 Controller Operation Quick Guide 5