Chapter 12 Operation of Zigzag Embroidery
3.
Zigzag Device Move Time: 2 (Default Value) —— User should set this value
according to the actual action time of zigzag device.
4.
Swing Range of Zigzag: 100 (Default Value). This value is the rotating angle of the
wheel. At the circumstance of thread-floating, user can decrease this value to relax the
influence as an assistant method. Generally, this value should be no less than 80.
5.
Top Speed of Zigzag: 600 (Default Value). The top speed can be set to 1000rpm, but
user needs set it on basis of the actual condition of machine.
6.
Thread-loosing Motor for Zigzag Embroidery: Yes/No. if the device is double motor
taping device, user needs to set it at “Y”, or user should set it as “N”.
7.
Zigzag Thread-loosing Adjustment Value: this is to adjust the thread-sending speed of
all the thread-loosing motors. The recommended value is 9.
8.
Frame Swing of Z5 Embroidery: by adjusting the frame, user can change the
embroidery range (The senior users are recommended to use this parameter).
9.
Zigzag Right Device Origin: this is for the angle between the threading point and the
direction of the mechanical origin of zigzag device at first needle position. Angle =
Parameter value *0.9. For an example, the parameter value is 80; the angle will be
80*0.9=72°.
10.
Zigzag Left Device Origin: this is for the angle between the threading point and the
direction of the mechanical origin of zigzag device at last needle position. Angle =
Parameter value *0.9. For an example, the parameter value is 80; the angle will be
80*0.9=72°.
11.
Zigzag Device Movement Detection: Test whether the device moves to the proper
position. User needs set this parameter according to the actual condition of the device.
12.
Test Thread-sending Motor of Zigzag Device (Y/N): The default value is “Y”. “Y”:
the thread-sending motor will not rotate until the position of hall component is
checked. “N”: The thread-sending motor will run as long as the system is at
embroidery status, regardless the position of the hall component. It can only be used
at the “107-P03-1.0” and higher version (for PC107 Board) or the “107B-JY-1.0 &
107B-DB-1.0” and higher version (for PC107B Board).
12.5
Relative Operations of Zigzag Embroidery
12.5.1.
Shift between Flat Embroidery Position and Zigzag
Embroidery Position
(1) Manual Shift
Owner’s Manual of BECS- 285A Computerized Control System
125