Appendix 1 Parameter List
No.
Name of Parameter
Default Value
Range of Value
Remarks
R Sequin
C65
Valve Time of Right
Sequin
0
0~5
D61
Motor Number of L
Sequin
No,1~4,1(2~4)
Set the parameter base on
sequin device. 2~4 mean
device number driven by one
motor
D62
Set 3MM of L
Sequin
One-way 6~40 steps;
Double-ways 6~40
steps
D63
Set 4MM of L
Sequin
One-way 6~40 steps;
Double-ways 6~40
steps
D64
Set 5MM of L
Sequin
One-way 6~40 steps;
Double-ways 6~40
steps
D65
Set 6.75MM of L
Sequin
One-way 6~40 steps;
Double-ways 6~40
steps
D66
Set 9MM of L
Sequin
One-way 6~40 steps;
Double-ways 6~40
steps
C61
A Size&Color of L
Sequin
5mm yellow 3/4/5/6.75/9mm
Yellow /Purple/Blue
/Green/Red/Golden/
Silver/Black
C62
B Size&Color of L
Sequin
5mm blue
3/4/5/6.75/9mm
Yellow/Purple/Blue
/Green/Red/Golden/
Silver/Black
C63
C Size&Color of L
Sequin
5mm silver
3/4/5/6.75/9mm
Yellow /Purple/Blue
/Green/Red/Golden/
Silver/Black
C64
D Size&Color of L
Sequin
5mm golden
3/4/5/6.75/9mm
Yellow /Purple/Blue
/Green/Red/Golden/
Silver/Black
D67
Sequin Gap Num of
L Sequin
No
No, 1,2
C66
Valve Time of Left
Sequin
0
0~5
D98
L.Knife Start Angle
Adj.
15
0~31
D99
R.Knife Start Angle
Adj.
15
0~31
Owner’s Manual of BECS- 285A Computerized Control System
145