Appendix 5 Automatic Limits Function for Cloth Embroidery/ Cap Embroidery
Appendix
5
Automatic
Limits Function for Cloth Embroidery/
Cap Embroidery
1. Working Principles
The automatic limits function is to use the X-/Y+ limits coupler as the origins. The system
will determine the embroidery range of that frame according to the frame size and the distance
between the origin and the set frame center (Unit: mm). Once the embroidery is over this range,
the controller will activate the automatic protection to prevent the mechanical device from
being damaged. There are 10 different default frames preset in the 285A controller, including 9
cloth embroidery frames and 1 cap embroidery frame.
2. Method for Setting the Automatic Limits of Cloth Embroidery
(1) Set Frame Origin
Use “Auto Frame Origin” to set the frame origin. The specific method is at below:
Turn the menu to the last page and click
to enter the “Other Function” menu
Select “Power-off Frame Protection/ Frame Origin” to enter the interface for setting the
frame origin
:
Owner’s Manual of BECS- 285A Computerized Control System
161