Appendix 5 Automatic Limits Function for Cloth Embroidery/ Cap Embroidery
Set the “Frame Selection” as “Cloth Frame Type A”. The frame will move to the position
(0, 0), which is the origin.
Measure the distance A (from needle plate hole to the right edge of frame) and distance B
(from the needle plate hole to the front edge of frame).
“X Center” X = A
-
L
/
2
;
“Y Center” Y = W
/
2
-
B
;
Fill the X and Y into the form as the X/Y Center for Cloth Frame A.
A
B
X
Y
164 Owner’s Manual of BECS- 285A Computerized Control System