Appendix 5 Automatic Limits Function for Cloth Embroidery/ Cap Embroidery
In the above picture, C is the preserved distance, which users can set according to their
devices. B is the available range of cap frame for embroidery in the Y direction.
“Y Center” Y = A
-
C
-
B
/
2.
Input the “X Center” X, “Y Center” Y and X/Y Embroidery Range for Cap Frame into the
parameters of “Cap Emb. Type J”.
Note:
“X Center” and “Y Center” can be adjusted manually, so that the error in
measurement can be minimized.
4. Cancellation of Automatic Limits for Cloth Embroidery/ Cap Embroidery
Set the “N” in the “Frame Selection” at “Frame Para. 2”, so that the automatic limits
function of cloth embroidery/ cap embroidery can be cancelled. At the same time, the software
protection on the flat embroidery frame will be invalid as well.
5. Size of Frames for Cloth Embroidery (Unit: mm)
Cloth Embroidery Frame A
:
Cloth Embroidery Frame B
:
Size
:
550×375 Size
:
290×290
Range
:
430×260 Range
:
230×230
A
B
C
Owner’s Manual of BECS- 285A Computerized Control System