Chapter 11 About JF Sequin Embroidery
Then you can select related operation for debugging.
11.9 Sequin Mending
After the thread breaks or the red thread-breakage detection indicator is turned on
manually, press the stop key to retreat and have the system enter the mending status. At
mending status, the sequin devices will go up and the machine will return and stop at the
mending point. Then user can press the Start key to perform the mending embroidery for
sequin. The mending embroidery will turn to the normal embroidery at the thread-breakage
point. Among the machine parameters, the “Patch Count” is unavailable in the in sequin
mending operation.
Owner’s Manual of BECS- 285A Computerized Control System
123