Chapter 4
Common Parameters and Color-Changing Order
4.1.7.
X-Y Reps
X Reps is the number of rows in repetition, and Y Reps is the number of columns in
repetition. The above diagram shows that X Reps is 3 and Y Reps is 2. The largest set value is
99*99.
4.1.8.
X-Y Interval
The above diagram also explains the meaning of this parameter.
4.2 Setting of Color-Changing Order
4.2.1.
Color-Changing Interface
No
Figure
Name
Description
1
Design
Display
Area
Display the design according to real-time
setting of color-changing order. Preview
the result of color-changing.
2
Needle Number
Selection Area
Select needle number here.
3
Current Position
Users can set, insert or delete needle bar
number in current position.
Owner’s Manual of BECS- 285A Computerized Control System