Chapter 32 Table of the Machine Parameters
Chapter 32
Table of the Machine Parameters
Note: Parameter 70~87 are only for machines with sequin embroidery function.
No.
Parameter
Suggested
Value
Note
1
FRAME
CURVE
&
ANGLE F2/260
F1
~
F6 are frame moving curves. The other figures
are starting angles for frame moving.
2
T.B. DETECT
Yes
“Yes”: auto detecting in case of thread break
“No”: no detecting in case of thread break
3
STOP AFTER T.B. DETECT
Yes
“Yes”: machine stop after thread break detected
“No”: machine doesn’t stop and the led blinks after
thread break detected
4
PRESS KEY AFTER T.B.
No
Press the confirmation key before pulling the bar
after thread break detection.
5
T.B. BACK STI.
0
How many stitches to move backward automatically
after thread break detect. Choice
:
0
~
7 stitches
,
6
PATCH
COUNT
(darning)
1
In repairing stitch, how many stitches to do before
the stop point. Choice
:
1
~
10 stitches
7
ACTION AFTER PATCHING
(darning)
SLOW
After repairing stitch, the main shaft can be:
SLOW,STOP,NO (change)
8
STI. NOT T.B. DETECT
8
Choice: 0
~
15stitches. It’s 8 if there is bottom thread
detect. It’s 3 for no bottom thread detect.
9
AUTO ORIGIN
Yes
The frame automatically returns to the origin point
after embroidery.
10
INITIALIZE
SYSTEM!
Parameters must be initialized for a new machine.
11
T.B. DETECT WHEN JUMP
No
Thread break detect in case jumping stitches. It
should be set according to the real needs.