Appendix 1 Parameter List
110
Owner’s Manual of BECS- A15 Computerized Control System
No.
Name of Parameter Default Value
Range of Value
Remarks
/green/blue/purple/yell
ow/cyanogen
C62
B Size&Color of L
Sequin
4mm blue
3/4/5/6.75/9mm
Light gray/gold/red
/green/blue/purple/yell
ow/cyanogen
C63
C Size&Color of L
Sequin
5mm purple
3/4/5/6.75/9mm
Light gray/gold/red
/green/blue/purple/yell
ow/cyanogen
C64
D Size&Color of L
Sequin
6.75mm gold
3/4/5/6.75/9mm
Light gray/gold/red
/green/blue/purple/yell
ow/cyanogen
D67
Sequin Gap Num
of L Sequin
No
No, 1,2
C66
Valve Time of Left
Sequin
0
0~5
D98
L.Knife Start Angle
Adj.
15
0~31
D60
Sequin Gap Num
of R Sequin
No
No, 1,2
C65
Valve Time of
Right Sequin
0
0~5
Taping Parameter
D86
A-Zig
Emb.Right
On/Off
Yes
Yes(First Stitch), No
D87
A-Zig
Emb.Left
On/Off
Yes
Yes(Last Stitch), No
D88
A-Zig Emb. On/Off
Time
2
C35
A-Zig Max Speed
400
300~850
D29
A-Zig Swing Angle 0
0~125
C38
A-Zig 5 Swing
Angle
0.2
0.2~10
D93
A-Zig T.L Adj
5
0~10
D95
A-TAPING
Emb.righe origin
pos.
0
0~100
D96
A-TAPING
Emb.left
origin
0
0~100