Appendix 3 Automatic Position Limitation Function Instructions for Apparel Embroidery
116
Owner’s Manual of BECS- A15 Computerized Control System
Appendix 3 Automatic Position Limitation Function Instructions
for Apparel Embroidery
A
、
Working Principle
The automatic position limitation function of single-head embroidery machine controller
is to determine the embroidery range of the frame by setting the distance from the center of the
frame to the origin (that is X-/Y position limitation optical coupler) and the actual frame size
(unit: mm). If embroidery is to be done beyond such range, the controller will activate
automatic protection to prevent damage to the mechanical parts of the embroidery machine.
B
、
Setting Method
1
、
Set Frame Origin
Press
key, then press
key, to enter the following interface.
Select "
⑨
Automatic Origin Search",
to enter the interface to search origin automatically;
the frame will search and determine the origin automatically; press "