Chapter 6
Memory Pattern
Management
50
Owner’s Manual of BECS- A15 Computerized Control System
2.
Select a pattern in the memory pattern image display area.
3.
Press
to enter memory operation selection interface.
4.
Press “Create Parameter Pattern” to enter the operation interface.
5.
User can press to input new pattern number and name instead of default ones.
6.
Press
to create the parameter pattern and return to pattern operation
selection interface. Press
to quit the creating operation and return to pattern
operation selection interface.
6.10
Mosaic Pattern
This operation is to combine two patterns into one new pattern. The interval of patterns
refers to the distance between the end of the first pattern and the start of the second pattern.
1.
Press
to enter memory pattern management interface.
2.
Select the two patterns to be combined and record their pattern numbers.
3.
Press
to enter memory operation selection interface.
4.
Press “Mosaic Pattern” to enter the operation interface.