Chapter 10 About JF Sequin Embroidery
Owner’s Manual of BECS- A15 Computerized Control System
79
Input design number and name, then click
to save the edited sequin design, or
click
to cancel the saving.
10.5
Setting of Multi-Sequin Embroidery Parameters
In this section, we will introduce how to adjust sequin device and the parameters used in
multi-sequin embroidery.
Press
in the main interface
,
select "Expert Param"
to enter parameter
management interface, then select Sequin Parameters to have access to the interface for setting
the sequin parameters.
1.
Limited Speed for Sequin R(L):
The parameter is to set the max speed during normal embroidery.
Note: the maximum speed of flat embroidery should be higher or equal to speed for
sequin embroidery.
2.
L/R Sequin Feeding Angle Adjustment
This parameter is to adjust the sequin-feeding angle.
3.
Auto Start for Sequin
When the setting is “Yes”, system will start embroidering sequin automatically.
When the setting is “No”, machine needs manually start at sequin embroidery.
4.
Time of Sequin Action
This is to set the time from sequin device going down to starting embroidery (0-15, the
default value is 2). If the sequin-feeding device is controlled by valve, use the default value; if
that device is controlled by motor, please set it at 4~5.
5.
Sequin off after T.B.
When the setting is “Yes”, sequin presser foot will be up automatically in case of