Chapter 11 D Type Sequin Embroidery
controlled by motor, choose 4-5.
4. Sequin off after T.B.
When the setting is “Yes”, sequin presser foot will be lift up automatically in case of
thread break.
When the setting is “No”, the sequin device needs manually lifting the presser foot.
5. Sequin Ind. Up Down
When the setting is “Yes”, it is independent lift up. When the setting is “No”, it is
collective lift up.
6. Up Value When Jump&NoCut
7. Motor Number of R (L) Sequin
The parameter setting should be based on actual device number, if there is no sequin
device, set to 0.
8. Set 3/4/5/6.75/9mm of R(L) Sequin
This is to set sequin delivery angle. If it is wheel, it should be set to single way; if it is
lever, it should be set to double way. The parameter is closely related to “left/right sequin
device A/B/C/D size and color”. For example, “A size&color of R sequin” is set to “4mm X
color”, and then the angle value should be “Set 4MM of R Sequin”.
9. A/B/C/D size&color of R/L sequin
Setting of this parameter depends on the mechanical structure. The order from A to D is
from front to back.
Note: “Motor Number of R (L) Sequin” is closely related to “A/B/C/D size&color of R/L
sequin”. For example, if “Motor Number of R (L) Sequin” is set to 2, then it only displays
“A/B size&color of R/L sequin”.
10. Sequin Gap Num of R(L) Sequin
This is to set gap number. If there is no gap, then it should be set to 0.
11. Valve Time of Right Sequin