Appendix 1 Parameter Setting List
142
BECS-D19 User’s Manual
No.
Parameter Name
Default
Range
Note
C69
Debouncing stitch
number for upper
thread detection
6 stitches 1
~
6 stitches
C70
Debouncing stitch
number for bobbin
thread detection
6 stitches 1
~
6 stitches
Frame Parameters
C06
Frame curve
F6
F1
~
F6
The high-speed all-servo machine
doesn’t have this parameter.
C06
Frame-moving angle
230
230~290
B03
Over frame by step
No
No, Yes
C15
High frame-moving
speed
16
1~30
C16
Low frame-moving
speed
15
1~30
D13
Over frame speed
16
0,1,2,…,30
D19
Use of pneumatic
frame
Yes
No, Yes
D20
Action interval of
pneumatic frame
3
0~15
C74
X direction
frame-moving angle A
245
230
~
280
Applicable for all-servo high-speed
machine
C75
X direction
frame-moving angle B
250
230
~
280
The same as above
C76
Y direction
frame-moving angle A
245
230
~
280
The same as above
C85
Y direction
frame-moving angle B
250
230
~
280
The same as above
C72
Embroidery mode
Tubular
Tubular, flat,
apparel
C73
Frame weight
1
0
~
20
Main Shaft Control Parameters
C07
Max. speed
700~850
250, 300, 350 …
1000
C09
Min. speed
400
250, 300, 350 …
600
C08
Shift stitch length (mm)
1.0~10.0
(normal type
machine),
3.0~6.0
(all-servo
high-speed
When the stitch length is longer than
the set value, the machine will lower
the speed.