Appendix 1 Parameter Setting List
BECS-D19 User’s Manual
143
No.
Parameter Name
Default
Range
Note
machine)
C10
Jump speed limit
500
400
~
750(normal type
machine),
400
~
1100
(all-servo
high-speed
machine)
Set the rotation speed for jump
stitch.
C13
Start stitch rotation
speed
80
80,90,…,150
C12
Low stitches at start
1
1~9 stitches
Set the number of slow stitches
before speed acceleration.
D02
Accelerated speed at
start
12
1,2,3,…,30
Increase the value to bring a quicker
speedup after pulling the bar.
C25
Stop position
compensation
0
0~30
Range: 0~30. When the main shaft
motor is an electromagnetic motor,
the value is usually set as 9. When it
is a servomotor, the parameter is
usually set as 5-7.
C24
Main shaft motor
parameter
1
0~30
The parameter is invalid when it’s a
servomotor. When it’s an
electromagnetic motor, increase this
parameter value to avoid main shaft
vibration during braking. Usually
it’s set as 1.
C14
Main shaft rotation
speed at slow action
400
80 (rpm), the
value of the
minimum speed
D14
Stop in position before
pulling bar
Yes
No, Yes
D10
Frequency conversion
transmission ratio
adjustment
0
-15% ~ +15%
The parameter is used when the
main shaft uses variable frequency
motor. If the value is incorrect, the
set rotation speed will be different
from the virtual speed.
C05
Thick cloth embroidery
compensation
0
0~3
C26
Needle stop at down
position adjustment
0
0~30
D53
Lock shaft at stop
Yes
Yes, No
Thread Trimming Parameters
C01
Jump trimming
3 stitches No trimming,