Appendix 4 Loop Embroidery Parameter List
BECS-D19 User’s Manual
157
lever single
sequin
F80
Sequin Auto
Start
No
Yes, No
Select auto start of sequin.
F81
Sequin Angle
13.5
5.4~36
°
Select chained sequin feeding angle.
Machine Configuration 1
F21
Shuttle Number
6
1~12
Set the shuttle number for each head
according to mechanical configuration.
F22
Head Number
10
1~24
Set head number according to mechanical
configuration.
F26
Chained
Embroidery
Head Board
XXX
1
XXX1,
XXX2
F36
Head
Adjustment
Value
100
0~250
This parameter is to set the reference value to
determine the needle height, used for
installing and debugging machine.
F37
Head Off
Position
138
138~250
Set the off position of head.
F38
Thread Loosing
Method
Md02
Md02,
e937
It is related to the requirement of drive input
signal. BBQ2003 is dual-impulse input, while
E937 is single-impulse input.
F48
Loop
Embroidery to
Flat Embroidery
Head Interval
-330.0
-600.0~600
.0
This parameter determines the frame moving
distance when switch between flat embroidery
head and loop embroidery head. It is up to the
machine condition.
F90
DIP1
Reserved
F91
DIP2
Reserved
F92
DIP3
Reserved
Machine Configuration 2
F93
DIP4
Reserved
F94
Main Shaft Lock Yes
Yes, No
Set whether to lock main shaft at stop (for
servo main shaft).
F95
AC
Color-changing
Box Position
Left
Left, Right
Set the position of AC color-changing box for
looping embroidery.
Blowing Parameters
F66
Stop Loops
3
1~6
F67
Blowing
Interval of
Looping Valve
15
0~200
F68
Blowing Time
of Looping
Valve
15
1~50