Chapter 5 Machine Parameter Management
BECS-D19 User’s Manual
61
adjustment. If user is not satisfied with the effects, he can press the swift key on the panel to
return to the parameter setting interface, where he can adjust the parameter again. Close the
parameter setting interface in the end.
4.
Forbid Pattern Output
The function is to forbid unauthorized copy of patterns from memory (into the disk). If the
machine administrator set “No Output Pattern” as “Yes”, other persons are unable to output the
patterns to the disk. If user needs to output, he has to release the setting of “No Output Pattern”
first.
5.3 Initialize Machine Parameters
This function can initialize the general embroidery parameters of the machine. System
saves a group of default parameter values. The manufacturer and embroidery factory
administrator can save their parameter settings. This operation need follow the rules at below:
1. When the manufacturer password and embroidery factory administrator password are
not set or the machine has no encryption function, all general embroidery parameters are
initialized to their default values.
2. When that manufacturer password has been set and unlocked, all general embroidery
parameters are initialized to their default values.
3. When that manufacturer password has been set and still locked but administrator
password has not been set or has been released, all manufacturer-authorized machine
parameters are recovered to the values saved by the manufacturer and other parameters are
initialized to the default values.
4. When both manufacturer password and administrator password have been set and still
locked, all manufacturer-authorized machine parameters are recovered to the values saved by
the manufacturer, all administrator-authorized machine application parameters are recovered to
the values set by administrator, and other parameters are initialized to their default values.
5. When that manufacturer password has not been set and administrator password has
been set but unlocked, all general embroidery parameters are initialized to their default values.
6. When that manufacturer password has not been set and administrator password has
been set but still locked, all administrator-authorized machine application parameters are
recovered to the values saved by administrator and other parameters are initialized to the
default values.
5.4 Machine Authorization Management
Note: This operation is fit for the machine with encryption function only.
For the convenient management of machine, general user can’t modify all parameters;
users are divided into three groups: general user, machine administrator and manufacturer user.
General user, having the lowest authorization, can only modify the embroidery parameters of
the machine, while machine administrator can also modify managing parameters, but only the
manufacturer user can modify all parameters.
Press “Machine Authorization Management” to enter the following interface.