9.Software Tools
© China Daheng Group, Inc. Beijing Image Vision Technology Branch 116
After selecting the GroupBox, when the above parameters are modified, the generated Lut will be written
to the device Flash in real time. At this time, the "Write To Device" is not selected. After the device is
powered off and restarted, the modified parameters will be lost. The generated Lut cannot be restored by
"Read From Device".
If the GroupBox is selected as default or standard Lut, then after adjusting the parameter values in the Lut
group, the generated Lut will be saved in the file together with the parameter values. While reading the file
again will restore the saved case. The MERCURY GigE, MARS-1230-9GM/C-P, MARS-880-13GM/C-P,
MARS-880-13GM/C-P ETR cameras will not save or restore the parameter while written to the device, but
the MERCURY2 GigE family, MARS-3140-3GM/C-P, MARS-2621-4GM-P ETR, MARS-2621-4GM-P NIR
ETR, MARS-2622-4GM-P ETR, MARS-2622-4GM-P NIR ETR cameras will.
9.2.2.4. Save Lut
The group contains two widgets: Save to File and Write to Device.
1. When selecting " Save to File ", the current Lut data can be saved to the file. The saved file contains
two formats: Lut and csv, as shown in Figure 9-11:
Figure 9-11 Save to file
The save type can be changed when saving the file. The default save path is
".\resource\gxplugins\LookUpTable\Lut12 ", which is the directory where the GalaxyView.exe is installed.
2. When "Write To Device" is selected, the current Lut data is written to UserSet0, and UserSetDefault
is modified to UserSet0. UserSet0 will be loaded when reading from the device again. MERCURY
USB3.0, USB2.0 camera does not support "Write To Device".