SECTION 3
EMERGENCY PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 3.5.5
Edition 1 -- November 30, 2010
Rev. 0
3.5 -- FIRE AND SMOKE
SMOKE ELIMINATION
1 -- Smoke origin
IDENTIFY
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -- Oxygen
USE AS REQUIRED
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(pilot and passengers)
3 -- If smoke persists, undertake an EMERGENCY DESCENT (Refer
to Chapter 3.6)
4 -- ”BLEED VALVE” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 -- “FREON” or “AIR COND” switch (if installed)
OFF
. . . . . . . . . . . .
6 -- ”DUMP” control
ACTUATE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wait until the differential pressure drops
7 -- ”RAM AIR” control knob
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If smoke increases
PUSH
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 -- LAND as soon as possible