3.9 -- ELECTRICAL SYSTEM
AMBER CAS MESSAGE
“MAIN GEN” ON
Indicates that ”GENERATOR” selector has been positioned to OFF or
ST--BY, or main generator is cut off
1 -- If necessary
CORRECT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -- If warning persists
”MAIN GEN” switching confirmed
. . . . . . . .
3 -- ”MAIN GENERATOR RESET” push--button
PUSH
. . . . . . . . . . . .
In case of failure :
4 -- Disconnect following ancillary electrical systems :
-- ”FREON” or “AIR COND” switch (if installed)
OFF
. . . . . . . . . .
-- ”STROBE” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”CABIN” lights switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”CABIN FAN” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”AP / TRIMS MASTER” switch
AP OFF
. . . . . . . . . . . . . . . . . . .
-- All equipment not essential
OFF
. . . . . . . . . . . . . . . . . . . . . . . . .
-- ”WINDSHIELD” switch
(above 15 000 ft)
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”BLEED VALVE” switch
(before landing and on ground)
OFF
. . . . . . . . . . . . . . . . . . . . . .
-- Only use landing lights briefly and if necessary.
5 -- ”GENERATOR” selector
ST-- BY
. . . . . . . . . . . . . . . . . . . . . . . . . . . .