TBM
PILOT’S OPERATING HANDBOOK
700
SECTION 3
EMERGENCY PROCEDURES
EASA Approved
Page 3.9.4
Edition 1 -- November 30, 2010
Rev. 0
3.9 -- ELECTRICAL SYSTEM
AMBER CAS MESSAGE
“LOW VOLTAGE” ON
functioning on ”ST--BY GENERATOR”
(after ”MAIN GEN” failure) (1/3)
Amber CAS messages
“MAIN GEN
and
“LOW VOLTAGE”
ON with
”GENERATOR” selector on ”ST--BY”
1 -- ”GENERATOR” selector
MAIN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -- ”MAIN GENERATOR RESET” push--button
PRESS
. . . . . . . . . . .
If successful :
3 -- Disconnect ancillary electrical systems not essential
4 -- Monitor voltmeter and ammeter
Prepare to SHORTEN FLIGHT
If not successful :
5 -- ”GENERATOR” selector
ST--BY
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 -- ”ST--BY GENERATOR RESET” push--button
PRESS
. . . . . . . . . .
If successful :
7 -- Disconnect ancillary electrical systems not essential
8 -- Monitor voltmeter and ammeter
Prepare to SHORTEN FLIGHT
If not successful, both generators failure is confirmed. If possible,
return to VMC conditions
9 -- ”GENERATOR” selector
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .