SECTION 3
EMERGENCY PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 3.9.5
Edition 1 -- November 30, 2010
Rev. 0
3.9 -- ELECTRICAL SYSTEM
AMBER CAS MESSAGE
“LOW VOLTAGE” ON
functioning on ”ST--BY GENERATOR”
(after ”MAIN GEN” failure) (2/3)
If conditions allow : VMC and non icing conditions
10 -- If altitude
≥
12000 ft : “OXYGEN” switch
ON
. . . . . . . . . . . . . . . . .
11 -- ”ESS BUS TIE” reverse switch
Cover up
. . . . . . . . . . . . . . . . . . . .
EMER position
In this configuration, only both ”ESS BUS” bars and ”BUS BAT” bar
are directly supplied by the battery
Available ancillary systems -- see Figure 3.9.1
12 -- LAND as soon as possible
If necessary, it is always possible to use other ancillary systems by
selecting :
-- ”ESS BUS TIE” reverse switch
NORMAL
. . . . . . . . . . . . . . . . . .
If flight conditions do not allow :
13 -- Manually disconnect ancillary systems as follows :
-- ”AIRFRAME DE ICE” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . .
-- ”ICE LIGHT” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”PROP DE ICE” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”WINDSHIELD” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”PITOT 2 & STALL HTR” switch
OFF
. . . . . . . . . . . . . . . . . . . . .
-- “L.LDG / TAXI / R.LDG / PULSE SYST” switches
OFF
. . . . . .
-- ”STROBE” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”BLEED / AIR COND” switches
OFF
. . . . . . . . . . . . . . . . . . . . . .
-- “AUX BP” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- “FUEL SEL” switch
MAN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- “AP TRIMS” MASTER switch
OFF
. . . . . . . . . . . . . . . . . . . . . . .
-- PFD 2 breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ADC 2 breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .