SECTION 3
EMERGENCY PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 3.10.3
Edition 1 -- November 30, 2010
Rev. 0
3.10 -- PRESSURIZATION AND AIR CONDITIONING
RED CAS MESSAGE ”BLEED TEMP” ON
Indicates overheat of air conditioning pack. Normally this leads to
”BLEED VALVE” cutoff and to
“BLEED OFF”
amber CAS message
appearance
Should automatic cutoff occur or not :
1 -- ”BLEED VALVE” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -- If necessary EMERGENCY DESCENT (Refer to Chapter 3.6) or
continue flight at an altitude < 12000 ft
REMARK :
Overheat may be due to a low airspeed in hot weather (beginning of
climb for example). In that case, a higher airspeed may be sufficient
to cause the overheat condition disappear, then ”BLEED TEMP”
CAS message will go out
In that case :
3 -- ”BLEED VALVE” switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 -- ”BLEED” selector
LO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 -- Continue flight