SECTION 3
EMERGENCY PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 3.11.3 (b)
Edition 1 -- November 30, 2010
Rev. 0
3.11 -- LANDING GEAR AND FLAPS
DISCREPANCY WHEN
LANDING GEAR GOES DOWN (1/2)
-- Red warning light on ”LANDING GEAR” control panel remains
flashing ON (whatever the condition of the green lights may be) :
The red warning light on the landing gear control panel flashing at the
end of maneuver indicates that the landing gear electrohydraulic
pump operates correctly.
1 -- ”LDG GR” circuit breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
If the red warning light goes off :
2 -- LAND.
If the red warning light remains fixed ON, apply the following procedure :
-- Red warning light on ”LANDING GEAR” control panel remains
fixed ON (whatever the condition of the green lights may be) :
The red warning light on the landing gear control panel is fixed ON at
the end of maneuver, the green indicator lights are ON or OFF, extend
the landing gear manually.
1 -- ”LDG GR” circuit breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -- Floor hatch
OPEN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 -- By--pass selector
FULLY PULL / LOCK
. . . . . . . . . . . . . . . . . . . . .
4 -- Landing gear control
DN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 -- Hand pump
ACTUATE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
with maximum amplitude
CAUTION
THE ENTIRE EXTENSION OF THE LANDING GEAR TAKES
ABOUT 65 CYCLES. IT IS MANDATORY TO HAVE A CLEAN
HARDENING OF THE MANUAL CONTROL AT THE END OF
THE MANEUVER
Post--MOD70--021--32