TBM
PILOT’S OPERATING HANDBOOK
700
SECTION 3
EMERGENCY PROCEDURES
EASA Approved
Page 3.13.6
Edition 1 -- November 30, 2010
Rev. 0
3.13 -- MISCELLANEOUS
OXYGEN USE (2/2)
NOTE :
Whenever an oxygen generator is activated, the CAS message
”OXYGEN” appears on the MFD unit.
The CAS message will remain ON as long as the used generator is not
replaced
AIRSPEED INDICATING SYSTEM FAILURE
Symptoms : erroneous indication in flight
1 -- ”PITOT 1 HTR” switch
CHECK ON
. . . . . . . . . . . . . . . . . . . . . . . . . .
2 -- ”PITOT 2 & STALL HTR” switch
CHECK ON
. . . . . . . . . . . . . . . . .
If symptoms persist :
3 -- ADC 2
SWITCH ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If symptoms persist :
4 -- ”ALTERNATE STATIC” selector
PULL THOROUGHLY
. . . . . . . . .
5 -- Use STBY airspeed indicator