SECTION 4
NORMAL PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 4.4.5
Edition 1 -- November 30, 2010
Rev. 0
AMPLIFIED PROCEDURES
PREFLIGHT INSPECTION (Cont’d)
27 -- Oxygen emergency system
WARNING CAS MESSAGE
“OXYGEN”
OFF
If not, seek which of the oxygen generators has been activated. The
amber strip around each generator becomes black by thermal
effect, if the generator has been operated. Moreover, check
regularly oxygen masks good condition, check them for correct
connection to their lanyards and that incorporated microphones
(pilot only) are correctly connected (in oxygen drawer) to radio
system. Oxygen emergency system in good operation condition
must be imperatively taken on board during all flights, even at low
altitude in order to be used in case of smoke in the cabin. Operation
of the system can not be checked ; only good condition of the
different components can be checked.
28 -- INT LIGHTS panel
CHECK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29 -- ECS panel
-- ”LT TEST” push button
(if vapor cycle cooling system installed)
PRESS
. . . . . . . . . . . . .
(green lamp ON)
30 -- CAS display
CHECK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31 -- Left and right fuel quantities
CHECK
. . . . . . . . . . . . . . . . . . . . . . . .
32 -- Flaps
LDG
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33 -- Landing gear panel
Warning lights : 3 GREEN ON
. . . . . . . . . . .
Test 1, then 2 : RED ON + 3 GREEN ON
”Test 1” and ”2” correspond to BUS bars 1 or 2, which feed them
respectively.