SECTION 4
NORMAL PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 4.4.21
Edition 1 -- November 30, 2010
Rev. 0
AMPLIFIED PROCEDURES
STARTING ENGINE USING AIRPLANE POWER (4/6)
-- Ng
The start sequence must be timed to ensure starter limits are not
exceeded. Lengthy operation of the starter results in excessive
temperature of the engine :
-- If Ng does not reach 30 % within 30 seconds, after the starter is
selected ON, abort the start.
-- If Ng does not reach 50 % within 1 minute, abort the start.
-- Before starting a new test, respect delays indicated in
Chapter 2.4 ”STARTER OPERATION LIMITS”.
-- Oil pressure
WARNING CAS MESSAGE
“OIL PRESS”
OFF
CAUTION
IF ENGINE IS SLOW TO START OR STAGNATES.
INTERRUPT STARTING PROCEDURE :
Condition lever
CUT OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
”IGNITION” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
”STARTER” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WAIT FOR 1 MINUTE (Refer to Chapter 2.4 ”STARTER
OPERATION LIMITS”), THEN TRY TO RESTART
ENGINE START panel
-- ”IGNITION” switch
AUTO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”STARTER” switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING CAS MESSAGE
“STARTER”
ON
WARNING CAS MESSAGE
“IGNITION”
ON
Ng
13 %
-- Condition lever
HI / IDLE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .