SECTION 4
NORMAL PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 4.4.27
Edition 1 -- November 30, 2010
Rev. 0
AMPLIFIED PROCEDURES
STARTING ENGINE USING
EXTERNAL POWER (GPU) (4/7)
CAUTION
IF 10 SECONDS AFTER HAVING POSITIONED CONDITION LEVER
TO ”LO / IDLE” THERE IS NO IGNITION OR IF DURING IGNITION
SEQUENCE, OVERTEMPERATURE INDICATION APPEARS
(MAX. ITT : 870
°
C FOR MORE THAN 20 SECONDS -- 1000
°
C FOR
MORE THAN 5 SECONDS),
INTERRUPT STARTING PROCEDURE :
Condition lever
CUT OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
”IGNITION” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wait ITT < 800
°
C, then :
”STARTER” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BEFORE ANY RESTARTING ATTEMPT, CARRY OUT A MOTORING
(Refer to paragraph ”MOTORING”)
CONTINUE WITH NORMAL PROCEDURE HEREAFTER
-- Ng
The start sequence must be timed to ensure starter limits are not
exceeded. Lengthy operation of the starter results in excessive
temperature of the engine :
-- If Ng does not reach 30 % within 30 seconds, after the starter is
selected ON, abort the start.
-- If Ng does not reach 50 % within 1 minute, abort the start.
-- Before starting a new test, respect delays indicated in
Chapter 2.4 ”STARTER OPERATION LIMITS”.
-- Oil pressure
WARNING CAS MESSAGE
“OIL PRESS”
OFF