SECTION 4
NORMAL PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 4.4.29
Edition 1 -- November 30, 2010
Rev. 0
AMPLIFIED PROCEDURES
STARTING ENGINE USING
EXTERNAL POWER (GPU) (6/7)
-- ”STARTER” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING CAS MESSAGE
“STARTER”
OFF
WARNING CAS MESSAGE
“IGNITION”
OFF
Engine instruments
CHECK Ng increasing to 69 % (
±
2 %)
. . . . . . .
(Oil pressure / ITT = green sector)
NOTE :
This behaviour should only be observed with outside low temperature
(OAT < 0
°
C), cold engine.
This procedure may be used for the first starting of the day.
CONTINUE WITH NORMAL PROCEDURE HEREAFTER
11 -- ”SOURCE” selector
BAT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING CAS MESSAGE
“BAT OFF”
OFF
12 -- Propeller governor lever
FEATHER
. . . . . . . . . . . . . . . . . . . . . . . .
This reduces propeller blast on the person disconnecting the GPU.
13 -- GPU
HAVE IT DISCONNECTED
. . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING CAS MESSAGE
“GPU DOOR”
OFF
This means that ground power receptacle door has been correctly
locked.
14 -- Condition lever
HI / IDLE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 -- Propeller governor lever
MAX. RPM
. . . . . . . . . . . . . . . . . . . . . . . .
16 -- Engine instruments
CHECK : Ng
69 % (
±
2 %)
. . . . . . . . . . . .
(Oil pressure / Oil temperature / ITT = green sector)