TBM
PILOT’S OPERATING HANDBOOK
700
SECTION 4
NORMAL PROCEDURES
EASA Approved
Page 4.4.32
Edition 1 -- November 30, 2010
Rev. 0
AMPLIFIED PROCEDURES
MOTORING (2/2)
2 -- FUEL panel
-- Tank selector
L or R
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”AUX BP” switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING CAS MESSAGE
“AUX BOOST PMP ON”
ON
WARNING CAS MESSAGE
“FUEL PRESS”
OFF
Fuel pressure is necessary for lubrication of HP pump.
3 -- ”IGNITION” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING CAS MESSAGE
“IGNITION”
OFF
To clear fuel and vapor internally trapped :
4 -- ”STARTER” switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
for 15 sec maxi
WARNING CAS MESSAGE
“STARTER”
ON
To cool engine following shut- down in high temperature
environment :
4 -- ”STARTER” switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
during 30 sec
WARNING CAS MESSAGE
“STARTER”
ON
If ignition symptoms occur (ITT increasing), check that ”IGNITION”
switch is OFF, that condition lever is on CUT OFF and continue motoring.
5 -- ”STARTER” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING CAS MESSAGE
“STARTER”
OFF
6 -- FUEL panel
-- ”AUX BP” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING CAS MESSAGE
“AUX BOOST PMP ON”
OFF
WARNING CAS MESSAGE
“FUEL PRESS”
ON