SECTION 4
NORMAL PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 4.4.37
Edition 1 -- November 30, 2010
Rev. 0
AMPLIFIED PROCEDURES
AFTER STARTING ENGINE (2/4)
-- ”CABIN FAN” switch
As required
. . . . . . . . . . . . . . . . . . . . . . .
There is no inconvenience to set ”CABIN FAN” switch ON before
starting engine for passenger and crew comfort, provided that
voltage is > 24.5 volts.
-- ”FREON” or “AIR COND” switch (if installed)
As required
. .
-- ”CABIN TEMP” selector
ADJUST
. . . . . . . . . . . . . . . . . . . . . . . .
Turn selector clockwise to increase temperature.
-- ”DEFOG / NORMAL” distributor
AS REQUIRED
. . . . . . . . . . . .
Usually selected to NORMAL. However, if canopy misting is
evident, select DEFOG and increase a little the cabin
temperature thanks to the ”CABIN TEMP” selector.
Cabin altitude selector
Airfield altitude - 500 feet
. . . . . . . . .
Cabin rate selector
ARROW UPWARDS
. . . . . . . . . . . . . . . . . .
(at the halfway post)
Such a selection will limit cabin rate selector at about
±
500 ft/min. If selector is turned to the right, limited values of
cabin rate selector increase.
6 -- Stand--by instruments
CHECKED
. . . . . . . . . . . . . . . . . . . . . . . . . . .
-- Suction gage
CHECKED
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 -- ADI/HSI on PFD1 / PFD2
CHECKED
. . . . . . . . . . . . . . . . . . . . . . . .
8 -- Altimeter setting
CHECKED
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 -- VHF/VOR/GPS
ADJUSTED -- TESTED
. . . . . . . . . . . . . . . . . . . . . .
-- Radar/Stormscope/TAS/TAWS/
Radio altimeter (if installed)
ADJUSTED -- TESTED
. . . . . . . . .
10 -- MFD flight management
-- Weight computing
SET/CHECKED
. . . . . . . . . . . . . . . . . . . . . . .
-- FOB synchro
SET
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- FPL (if requested)
SET
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .